Borate fusion is a technique used to prepare various types of samples for subsequent XRF analysis, ICP analysis or AA analysis.

How borate fusion works

The borate fusion technique consists of mixing a ground sample with a borate flux (lithium or sodium) inside a 95% Pt - 5% Au crucible, heating to 1000 °C with agitation until the flux melts, and then dissolving the sample homogeneously in the flux. When the sample needs to be prepared for X-ray fluorescence (XRF analysis), the hot melt is then cast into a mold and cooled, resulting in a glass disk. The melt can otherwise be poured into diluted acid for subsequent inductively coupled plasma (ICP analysis) or atomic absorption (AA analysis).

Significant benefits that make the difference

Since XRF is a comparative technique, the standards used to prepare the calibration curve have to closely match the characteristics of the unknown sample to provide an accurate and precise analysis. Fusion is the only sample preparation technique that allows you to matrix-match the standards and unknown that cover a wide range of materials. The glass disks prepared by borate fusion lead to XRF analytical results that are far more precise and accurate than the ones obtained with pressed pellets. In addition of being simple, fast and effective, this preparation technique reduces the number of certified reference materials and calibration applications.  Fusion is also well-suited to prepare samples for ICP analysis and AA analysis since unlike common acid digestion techniques, it allows the complete digestion/dissolution of highly refractory materials, ferroalloys and sulfides. It is also safer for the operator (no use of dangerous acids such as HF and HClO4), faster and automated.

Claisse LeNeo

Claisse TheOx Advanced

Claisse Eagon 2

Claisse M4

Claisse LeDoser-12

Claisse LeDoser

Claisse rFusion

Claisse LeNeo

Claisse 借助熔融专业知识,助您保持领先地位

Claisse TheOx Advanced

即时获得高生产率!

Claisse Eagon 2

安全、简单、高性能

Claisse M4

以熔融方式制备样品的标准设备

Claisse LeDoser-12

及时称重,实现最佳精度和可重复性!

Claisse LeDoser

提升分析精度

Claisse rFusion

让 Claisse rFusion 为您效力

更多细节 更多细节 更多细节 更多细节 更多细节 更多细节 更多细节
加热模式 Electric Electric Electric Gas Gas
每个熔融周期的样品数量 1 6 2 3 6
生产率 Glass disks (XRF) : up to 4 per hour; Borate and peroxide solutions (ICP-AA): up to 6 per hour Glass disks (XRF): up to 24 per hour; Borate and peroxide solutions (ICP-AA): up to 36 per hour Glass disks (XRF) : up to 8 per hour Glass disks (XRF): up to 12 per hour; Borate solutions (ICP-AA): up to 24 per hour Runs autonomously for up to 250 weighings (depending on quantity of flux) Runs autonomously for up to 250 weighings (depending on quantity of flux) Glass disks (XRF): up to 24 per hour; Borate solutions (ICP-AA): up to 48 per hour